Reference Guide

70 Storage Management Message Reference
2094 Predictive Failure
reported.
Warning /
Non-critical
Cause: The physical disk is predicted to fail.
Many physical disks contain Self Monitoring
Analysis and Reporting Technology (SMART).
When enabled, SMART monitors the health
of the disk based on indications such as the
number of write operations that have been
performed on the disk.
Action: Replace the physical disk. Even
though the disk may not have failed yet, it is
strongly recommended that you replace the
disk.
If this disk is part of a redundant virtual disk,
perform the Offline task on the disk; replace
the disk; and then assign a hot spare and the
rebuild will start automatically.
If this disk is a hot spare, then unassign the
hot spare; perform the Prepare to Remove
task on the disk; replace the disk; and assign
the new disk as a hot spare.
NOTICE: If this disk is part of a
nonredundant disk, back up your data
immediately. If the disk fails, you will not
be able to recover the data.
None 903
Table 4-4. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action Clear
Event
Number
SNMP