Reference Guide

Storage Management Message Reference 73
2104 Controller battery is
reconditioning
Ok / Normal Cause: This alert is for informational purposes.
Action: None
2105 1151
2105 Controller battery
recondition is
completed
Ok / Normal Cause: This alert is for informational purposes.
Action: None
Clear
event
1151
2106 Smart FPT exceeded Warning /
Non-critical
Cause: A disk on the specified controller has
received a SMART alert (predictive failure)
indicating that the disk is likely to fail in the
near future.
Action: Replace the disk that has received the
SMART alert. If the physical disk is a
member of a non-redundant virtual disk,
then back up the data before replacing the
disk.
NOTICE: Removing a physical disk that is
included in a non-redundant virtual disk
will cause the virtual disk to fail and may
cause data loss.
None 903
2107 Smart configuration
change
Critical /
Failure /
Error
Cause: A disk has received a SMART alert
(predictive failure) after a configuration
change. The disk is likely to fail in the near
future.
Action: Replace the disk that has received the
SMART alert. If the physical disk is a
member of a non-redundant virtual disk,
then back up the data before replacing the
disk.
NOTICE: Removing a physical disk that is
included in a non-redundant virtual disk
will cause the virtual disk to fail and may
cause data loss.
None 904
Table 4-4. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action Clear
Event
Number
SNMP
Trap
Numbers