Reference Guide

76 Storage Management Message Reference
2110 SMART warning
degraded
Warning /
Non-critical
Cause: A disk is degraded and has received a
SMART alert (predictive failure). The disk is
likely to fail in the near future.
Action: Replace the disk that has received the
SMART alert. If the physical disk is a
member of a non-redundant virtual disk,
then back up the data before replacing the
disk.
NOTICE: Removing a physical disk that is
included in a non-redundant virtual disk
will cause the virtual disk to fail and may
cause data loss.
None 903
2111 Failure prediction
threshold exceeded
due to test - No
action needed
Warning /
Non-critical
Cause: A disk has received a SMART alert
(predictive failure) due to test conditions.
Action: None
None 903
2112 Enclosure was shut
down
Critical /
Failure /
Error
Cause: The physical disk enclosure is either
hotter or cooler than the maximum or
minimum allowable temperature range.
Action: Check for factors that may cause
overheating or excessive cooling. For example,
verify that the enclosure fan is working. You
should also check the thermostat settings and
examine whether the enclosure is located
near a heat source. Make sure the enclosure
has enough ventilation and that the room
temperature is not too hot or too cold. See
the enclosure documentation for more
diagnostic information.
None 854
2114 A consistency check
on a virtual disk has
been paused
(suspended)
Ok / Normal Cause: The check consistency operation on a
virtual disk was paused by a user.
Action: To resume the check consistency
operation, right-click the virtual disk in the
tree view and select Resume Check
Consistency.
2115 1201
Table 4-4. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action Clear
Event
Number
SNMP
Trap
Numbers