Reference Guide

Storage Management Message Reference 79
2123 Redundancy lost Warning /
Non-critical
Cause: A virtual disk or an enclosure has lost
data redundancy. In the case of a virtual disk,
one or more physical disks included in the
virtual disk have failed. Due to the failed
physical disk or disks, the virtual disk is no
longer maintaining redundant (mirrored or
parity) data. The failure of an additional
physical disk will result in lost data. In the
case of an enclosure, more than one enclosure
component has failed. For example, the
enclosure may have suffered the loss of all
fans or all power supplies.
Action: Identify and replace the failed
components. To identify the failed component,
select the Storage object and click the Health
subtab. The controller status displayed on the
Health subtab indicates whether a controller
has a failed or degraded component. Click
the controller that displays a Warning or
Failed status. This action displays the controller
Health subtab which displays the status of
the individual controller components.
Continue clicking the components with a
Warning or Health status until you identify
the failed component.
See the online help for more information. See
the enclosure documentation for information
on replacing enclosure components and for
other diagnostic information.
2124 1306
2124 Redundancy normal Ok / Normal Cause: This alert is for informational purposes.
Data redundancy has been restored to a
virtual disk or an enclosure that previously
suffered a loss of redundancy.
Action: None
Clear
event
1304
Table 4-4. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action Clear
Event
Number
SNMP
Trap
Numbers