Reference Guide

80 Storage Management Message Reference
2126 SCSI sense sector
reassign
Warning /
Non-critical
Cause: A sector of the physical disk is
corrupted and data cannot be maintained on
this portion of the disk. This alert is for
informational purposes.
NOTICE: Any data residing on the
corrupt portion of the disk may be lost
and you may need to restore your data
from backup.
Action: If the physical disk is part of a
nonredundant virtual disk, then back up the
data and replace the physical disk.
NOTICE: Removing a physical disk that is
included in a nonredundant virtual disk
will cause the virtual disk to fail and may
cause data loss.
If the disk is part of a redundant virtual disk,
then any data residing on the corrupt portion
of the disk will be reallocated elsewhere in the
virtual disk.
None 903
2127 Background
initialization (BGI)
started
Ok / Normal Cause: BGI of a virtual disk has started. This
alert is for informational purposes.
Action: None
2130 1201
2128 BGI cancelled Ok / Normal Cause: BGI of a virtual disk has been
cancelled. A user or the firmware may have
stopped BGI.
Action: None
None 1201
2129 BGI failed Critical /
Failure /
Error
Cause: BGI of a virtual disk has failed.
Action: None
None 1204
2130 BGI completed Ok / Normal Cause: BGI of a virtual disk has completed.
This alert is for informational purposes.
Action: None
Clear
event
1201
Table 4-4. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action Clear
Event
Number
SNMP
Trap
Numbers