Reference Guide

88 Storage Management Message Reference
2171 The controller
battery temperature
is above normal.
Warning /
Non-critical
Cause: The battery may be recharging, the
room temperature may be too hot, or the fan
in the system may be degraded or failed.
Action: If this alert was generated due to a
battery recharge, the situation will correct
when the recharge is complete. You should
also check if the room temperature is normal
and that the system components are
functioning properly.
2172 1153
2172 The controller
battery temperature
is normal.
Ok / Normal Cause: This alert is for informational purposes.
Action: None
Clear
event
1151
2173 Unsupported
configuration
detected. The SCSI
rate of the enclosure
management
modules (EMMs) is
not the same.
EMM0 %1 EMM1
%2
Warning /
Non-critical
Cause: The EMMs in the enclosure have a
different SCSI rate. This is an unsupported
configuration. All EMMs in the enclosure
should have the same SCSI rate. The %
(percent sign) indicates a substitution
variable. The text for this substitution
variable is displayed with the alert in the Alert
Log and can vary depending on the situation.
Action: The EMMs in the enclosure have a
different SCSI rate. This is an unsupported
configuration. All EMMs in the enclosure
should have the same SCSI rate.
None 853
2174 The controller
battery has been
removed.
Warning /
Non-critical
Cause: The controller cannot communicate
with the battery, the battery may be removed,
or the contact point between the controller
and the battery may be burnt or corroded.
Action: Replace the battery if it has been
removed. If the contact point between the
battery and the controller is burnt or corroded,
you will need to replace either the battery or
the controller, or both. See the hardware
documentation for information on how to
safely access, remove, and replace the battery.
None 1153
2175 The controller
battery has been
replaced.
Ok / Normal Cause: This alert is for informational purposes.
Action: None
None 1151
Table 4-4. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action Clear
Event
Number
SNMP
Trap