Reference Guide

90 Storage Management Message Reference
2182 An invalid SAS
configuration has
been detected.
Critical /
Failure /
Error
Cause: The controller and attached
enclosures are not cabled correctly.
Action: See the hardware documentation for
information on correct cabling
configurations.
None 754
2186 The controller cache
has been discarded.
Warning /
Non-critical
Cause: The controller has flushed the cache
and any data in the cache has been lost. This
may happen if the system has memory or
battery problems that cause the controller to
distrust the cache. Although user data may have
been lost, this alert does not always indicate
that relevant or user data has been lost.
Action: Verify that the battery and memory
are functioning properly.
None 753
2187 Single-bit ECC error
limit exceeded.
Warning /
Non-critical
Cause: The system memory is
malfunctioning.
Action: Replace the battery pack.
None 753
2188 The controller write
policy has been
changed to Write
Through.
Warning /
Non-critical
Cause: The controller battery is unable to
maintain cached data for the required period
of time. For example, if the required period of
time is 24 hours, the battery is unable to
maintain cached data for 24 hours. It is
normal to receive this alert during the battery
Learn cycle as the Learn cycle discharges the
battery before recharging it. When
discharged, the battery cannot maintain
cached data.
Action: Check the health of the battery. If the
battery is weak, replace the battery pack.
None 1153
2189 The controller write
policy has been
changed to Write
Back.
Ok / Normal Cause: This alert is for informational purposes.
Action: None
None 1151
Table 4-4. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action Clear
Event
Number
SNMP