Reference Guide

Storage Management Message Reference 91
2191 Multiple enclosures
are attached to the
controller. This is an
unsupported
configuration.
Critical /
Failure /
Error
Cause: Many enclosures are attached to the
controller port. When the enclosure limit is
exceeded, the controller loses contact with all
enclosures attached to the port.
Action: Remove the last enclosure. You must
remove the enclosure that has been added last
and is causing the enclosure limit to exceed.
None 854
2192 The virtual disk
Check Consistency
has made corrections
and completed.
Ok / Normal Cause: This alert is for informational purposes.
The virtual disk Check Consistency has
identified errors and made corrections. For
example, the Check Consistency may have
encountered a bad disk block and remapped
the disk block to restore data consistency.
Action: Monitor the battery and cache health
to make sure they are functioning properly.
Monitor the Alert Log for events related to
the battery and to write policy changes. You
should also monitor the Alert Log for events
related to disk errors. If you suspect that the
battery or a disk has problems, replace the
battery pack or the disk.
None 1203
2193 The virtual disk
reconfiguration has
resumed.
Ok / Normal Cause: This alert is for informational purposes.
Action: None
None 1201
2194 The virtual disk
Read policy has
changed.
Ok / Normal Cause: This alert is for informational purposes.
Action: None
None 1201
2195 Dedicated hot spare
assigned. Physical
disk %1
Ok / Normal Cause: This alert is for informational purposes.
Action: None.
2196 1201
2196 Dedicated hot spare
unassigned. Physical
disk %1
Ok / Normal Cause: This alert is for informational purposes.
Action: None.
Clear
event
1201
2199 The virtual disk
cache policy has
changed.
Ok / Normal Cause: This alert is for informational purposes.
Action: None
None 1201
Table 4-4. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action Clear
Event
Number
SNMP
Trap