Reference Guide

Storage Management Message Reference 93
2205 A dedicated hot
spare has been
automatically
unassigned.
Warning /
Non-critical
Cause: The hot spare is no longer required
because the virtual disk it was assigned to has
been deleted.
Action: None.
None 903
2206 The only hot spare
available is a
SATA disk. SATA
disks cannot replace
SAS disks.
Warning /
Non-critical
Cause: The only physical disk available to
be assigned as a hot spare is using
SATA technology. The physical disks in the
virtual disk are using SAS technology.
Because of this difference in technology, the
hot spare cannot rebuild data if one of the
physical disks in the virtual disk fails.
Action: Add a SAS disk that is large enough
to be used as the hot spare and assign the new
disk as a hot spare.
None 903
2207 The only hot spare
available is a SAS
disk. SAS disks
cannot replace SATA
disks.
Warning /
Non-critical
Cause: The only physical disk available to be
assigned as a hot spare is using SAS technology.
The physical disks in the virtual disk are using
SATA technology. Because of this difference
in technology, the hot spare cannot rebuild
data if one of the physical disks in the virtual
disk fails.
Action: Add a SATA disk that is large enough
to be used as the hot spare and assign the new
disk as a hot spare.
None 903
2211 The physical disk is
not supported.
Warning /
Non-critical
Cause: The physical disk may not have a
supported version of the firmware or the disk
may not be supported by Dell.
Action: If the disk is supported by Dell,
update the firmware to a supported version.
If the disk is not supported by Dell, replace
the disk with one that is supported.
None 903
2212 The controller
battery temperature
is above normal.
OK/Normal Cause: This alert is for informational purposes.
Action: None
None 1151
2213 Recharge count
maximum exceeded
Warning /
Non-critical
Cause: The battery has been recharged more
times than the battery recharge limit allows.
Action: Replace the battery pack.
None 1153
Table 4-4. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action Clear
Event
Number
SNMP
Trap
Numbers