2273 Bad media. Critical /
Failure /
Error
Cause: A source (array) disk in a redundant
virtual disk has a bad disk block. The algorithm
that maintains redundant data has created a
similar bad block on the target redundant
disk to maintain consistency in disk block
addressing. Data has been lost.
Action: Restore from backup.
None 904
2274 The physical disk
rebuild has resumed.
Ok / Normal Cause: This alert is for informational purposes.
Action: None
None 901
2276 The dedicated hot
spare is too small.
Warning /
Non-critical
Cause: The dedicated hot spare is not large
enough to protect all virtual disks that reside
on the disk group.
Action: Assign a larger disk as the dedicated
hot spare.
None 903
2277 The global hot spare
is too small.
Warning /
Non-critical
Cause: The global hot spare is not large enough
to protect all virtual disks that reside on the
controller.
Action: Assign a larger disk as the global
hot spare.
None 903
2278 The controller
battery charge level
is below a normal
threshold.
Ok / Normal Cause: The battery is discharging. A battery
discharge is a normal activity during the
battery Learn cycle. Before completing, the
battery Learn cycle recharges the battery. You
should receive alert 2179 when the recharge
occurs.
Action: Check if the battery Learn cycle is in
progress. Alert 2176 indicates that the battery
Learn cycle has initiated. The battery also
displays the Learn state while the Learn cycle
is in progress. If a Learn cycle is not in
progress, replace the battery pack.
None 1154
2279 The controller
battery charge level
is above a normal
threshold.
Ok / Normal Cause: This alert is for informational purposes.
This alert indicates that the battery is
recharging during the battery Learn cycle.
Action: None
None 1151
Table 4-4. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action Clear
Event
Number