Remote Access Service 83
5
Configure numeric paging (for DRAC III users only):
a
Click the check box next to
Enable Numeric Paging
and enter a pager number in the
Pager Number
field.
b
Enter the numeric message in the
Numeric Message
field that you want the DRAC to send when
it receives certain events.
6
Configure e-mail paging:
a
Click the check box next to
Enable Email Paging
and enter an e-mail address in the
Email Address
field.
b
Enter the message in the
Message
field that you want the DRAC to send when it receives
certain events.
7
Configure alphanumeric paging (for DRAC III users only):
a
Click the check box next to
Enable Alpha-Numeric Paging
and enter a pager number in the
Pager Number
field.
b
Select the alphanumeric protocol used by the pager's service provider,
7E0
or
8N1
.
c
Select the pager's baud rate,
300
or
1200
.
d
Enter the message in the
Custom Message
field that you want the DRAC to send when it receives
certain events.
e
Enter the pager's PIN in the
Pager ID
field, and then, if required, enter a pager password in the
Pager Password
field.
f
Click
Apply Changes
at the bottom of the window.
8
Under
Severity Configuration
, specify the trap and the severity that the trap must have to trigger a
paging action from the DRAC.
Traps enable you to configure the DRAC to respond to alert conditions from the system's ESM
hardware or to other conditions such as operating system crashes or power failures.
The first (left-most) column of check boxes corresponds to the severity level
Informational
, the
second column corresponds to the severity level
Warning
, and the third column corresponds to the
severity level
Critical
. The last seven events can only report the severity level
Informational
.
9
Click
Apply Changes
and then click
OK
to save the alert, paging, and user configuration to the Server
Administrator data repository.
Server Administrator returns you to the
Users
tab.