Messages Reference Guide

Storage Management Message Reference 103
2207 The only hot
spare available
is a SAS disk.
SAS disks
cannot replace
SATA disks.
Warning /
Non-critical
Cause: The only physical disk
available to be assigned as a hot spare
is using SAS technology. The physical
disks in the virtual disk are using
SATA technology. Because of this
difference in technology, the hot
spare cannot rebuild data if one of
the physical disks in the virtual disk
fails.
Action: Add a SATA disk that is large
enough to be used as the hot spare
and assign the new disk as a hot
spare.
Clear Alert Number: None.
Related Alert Number: None.
LRA Number: 2070
903
2211 The physical
disk is not
supported.
Warning /
Non-critical
Cause: The physical disk may not
have a supported version of the
firmware or the disk may not be
supported by Dell.
Action: If the disk is supported by
Dell, update the firmware to a
supported version. If the disk is not
supported by Dell, replace the disk
with one that is supported.
Clear Alert Number: None.
Related Alert Number: None.
LRA Number: 2070
903
2212 The controller
battery
temperature is
above normal.
OK/Normal Cause: This alert is for informational
purposes.
Action: None
Clear Alert Number: None.
Related Alert Number: None.
LRA Number: None.
1151
2213 Recharge
count
maximum
exceeded
Warning /
Non-critical
Cause: The battery has been
recharged more times than the
battery recharge limit allows.
Action: Replace the battery pack.
Clear Alert Number: None.
Related Alert Number: None.
LRA Number: 2100
1153
2214 Battery charge
in progress
OK/Normal Cause: This alert is for informational
purposes.
Action: None.
Clear Alert Number: None.
Related Alert Number: None.
LRA Number: None.
1151
Table 4-4. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action Related Alert Information SNMP
Trap
Numbers