Messages Reference Guide

Storage Management Message Reference 109
2267 The controller
reconstruct
rate has
changed.
Ok / Normal Cause: This alert is for informational
purposes.
Action: None
Clear Alert Number: None.
Related Alert Number: None.
LRA Number: None.
751
2268 %1, Storage
Management
has lost
communicatio
n with the
controller. An
immediate
reboot is
strongly
recommended
to avoid
further
problems. If
the reboot
does not
restore
communicatio
n, then contact
technical
support for
more
information.
Critical /
Failure /
Error
Cause: Storage Management has lost
communication with a controller.
This may occur if the controller
driver or firmware is experiencing a
problem. The %1 indicates a
substitution variable. The text for
this substitution variable is displayed
with the alert in the Alert Log and
can vary depending on the situation.
Action: Reboot the system. If the
problem is not resolved, contact
technical support. See your system
documentation for information
about contacting technical support
by using telephone, fax, and Internet
services.
Clear Alert Number: None.
Related Alert Number: None.
LRA Number: 2051
104
2269 The physical
disk Clear
operation has
completed.
Ok / Normal Cause: This alert is for informational
purposes.
Action: None
Clear Alert Number: None.
Related Alert Number: None.
LRA Number: None.
901
Table 4-4. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action Related Alert Information SNMP
Trap
Numbers