Messages Reference Guide

Storage Management Message Reference 117
2300 The enclosure
is unstable.
Critical /
Failure /
Error
Cause: The controller is not receiving
a consistent response from the
enclosure. There could be a firmware
problem or an invalid cabling
configuration. If the cables are too
long, they will degrade the signal.
Action: Power down all enclosures
attached to the system and reboot
the system. If the problem persists,
upgrade the firmware to the latest
supported version. You can download
the most current version of the driver
and firmware from support.dell.com.
Make sure the cable configuration is
valid. See the hardware
documentation for valid cabling
configurations.
Clear Alert Number: None.
Related Alert Number: None.
LRA Number: 2091
854
2301 The enclosure
has a hardware
error.
Critical /
Failure /
Error
Cause: The enclosure or an enclosure
component is in a Failed or Degraded
state.
Action: Check the health of the
enclosure and its components.
Replace any hardware that is in a
Failed state. See the hardware
documentation for more
information.
Clear Alert Number: None.
Related Alert Number: None.
LRA Number: 2091
854
2302 The enclosure
is not
responding.
Critical /
Failure /
Error
Cause: The enclosure or an enclosure
component is in a Failed or Degraded
state.
Action: Check the health of the
enclosure and its components.
Replace any hardware that is in a
Failed state. See the hardware
documentation for more
information.
Clear Alert Number: None.
Related Alert Number: None.
LRA Number: 2091
854
Table 4-4. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action Related Alert Information SNMP
Trap
Numbers