Messages Reference Guide

Storage Management Message Reference 121
2314 The
initialization
sequence of
SAS
components
failed during
system startup.
SAS
management
and
monitoring is
not possible.
Critical /
Failure /
Error
Cause: Storage Management is
unable to monitor or manage SAS
devices.
Action: Reboot the system. If
problem persists, make sure you have
supported versions of the drivers and
firmware. Also, you may need to
reinstall Storage Management or
Server Administrator because of
some missing installation
components.
Clear Alert Number: None.
Related Alert Number: None.
LRA Number: 2051
104
2315 Diagnostic
message %1
Ok / Normal Cause: This alert is for informational
purposes. The %1 indicates a
substitution variable. The text for
this substitution variable is generated
by the utility that ran the diagnostics
and is displayed with the alert in the
Alert Log. This text can vary
depending on the situation.
Action: None
Clear Alert Number: None.
Related Alert Number: None.
LRA Number: None.
751
2316 Diagnostic
message %1
Critical /
Failure /
Error
Cause: A diagnostics test failed. The
%1 indicates a substitution variable.
The text for this substitution variable
is generated by the utility that ran the
diagnostics and is displayed with the
alert in the Alert Log. This text can
vary depending on the situation.
Action: See the documentation for
the utility that ran the diagnostics for
more information.
Clear Alert Number: None.
Related Alert Number: None.
LRA Number: 2061
754
2318 Problems with
the battery or
the battery
charger have
been detected.
The battery
health is poor.
Warning /
Non-critical
Cause: The battery or the battery
charger is not functioning properly.
Action: Replace the battery pack.
Clear Alert Number: None.
Related Alert Number: 2188
LRA Number: 2100
1154
Table 4-4. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action Related Alert Information SNMP
Trap
Numbers