Messages Reference Guide

Storage Management Message Reference 123
2323 The power
supply is
switched on.
Ok / Normal Cause: This alert is for informational
purposes.
Action: None
Clear Alert Status: Alert 2323 is
a clear alert for alerts 2313 and
2322.
Related Alert Number: None.
LRA Number: None.
1001
2324 The AC power
supply cable
has been
removed.
Critical /
Failure /
Error
Cause: The power cable may be
pulled out or removed. The power
cable may also have overheated and
become warped and nonfunctional.
Action: Replace the power cable.
Clear Alert Number: 2325.
Related Alert Number: None.
LRA Number: 2091
1004
2325 The power
supply cable
has been
inserted.
Ok / Normal Cause: This alert is for informational
purposes.
Action: None
Clear Alert Status: Alert 2325 is
a clear alert for alerts 2324 and
2312.
Related Alert Number: None.
LRA Number: None.
1001
2326 A foreign
configuration
has been
detected.
Ok / Normal Cause: This alert is for informational
purposes. The controller has physical
disks that were moved from another
controller. These physical disks
contain virtual disks that were created
on the other controller. See the Import
Foreign Configuration and Clear
Foreign Configuration section in the
Dell OpenManage Server
Administrator Storage Management
User’s Guide for more information.
Action: None
Clear Alert Number: None.
Related Alert Number: None.
LRA Number: None.
751
Table 4-4. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action Related Alert Information SNMP
Trap