Messages Reference Guide

Storage Management Message Reference 133
2367 Rebuild not
possible as
SAS/SATA is
not supported
in the same
virtual disk.
Warning /
Non-critical
Cause: The physical disk is using an
incompatible technology.
Action: All physical disks in the
virtual disk must use the same
technology. You cannot use both SAS
and SATA physical disks in the same
virtual disk. Remove the physical disk
and insert a new physical disk that
uses the correct technology. If the
rebuild does not start automatically
after you have inserted a suitable
physical disk, then run the Rebuild
task.
Clear Alert Number: None.
Related Alert Number: 2326
LRA Number: 2070
903
2368 The SCSI
Enclosure
Processor
(SEP) has been
rebooted as
part of the
firmware
download
operation and
will be
unavailable
until the
operation
completes.
Ok / Normal Cause: This alert is for informational
purposes.
Action: None.
Clear Alert Number: None.
Related Alert Number: 2049,
2052, 2162, 2292
LRA Number: None.
851
2369 Virtual Disk
Redundancy
has been
degraded.
Ok / Normal Cause: A physical disk in a RAID 6
virtual disk has either failed or been
removed.
Action: Replace the missing or failed
physical disk.
Clear Alert Number: 2121.
Related Alert Number: 2048,
2049, 2050, 2076, 2346
LRA Number: None.
1201
2371 Attempted
import of
Unsupported
Virtual Disk
type RAID%1
Ok / Normal Cause: This alert is for informational
purposes.
Action: None.
Clear Alert Number: None.
Related Alert Number: None.
LRA Number: None.
751
Table 4-4. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action Related Alert Information SNMP
Trap