2076 Virtual disk
check
consistency
failed
Critical /
Failure /
Error
Cause: A physical disk included in
the virtual disk failed or there is an
error in the parity information. A
failed physical disk can cause errors in
parity information.
Action: Replace the failed physical
disk. You can identify which disk has
failed by locating the disk that has a
red “X” for its status. Rebuild the
physical disk. When finished, restart
the check consistency operation.
Clear Alert Number: None.
Related Alert Number: None.
LRA Number: 2081
1204
2077 Virtual disk
format failed.
Critical /
Failure /
Error
Cause: A physical disk included in
the virtual disk failed.
Action: Replace the failed physical
disk. You can identify which physical
disk has failed by locating the disk
that has a red "X" for its status.
Rebuild the physical disk. When
finished, restart the virtual disk
format operation.
Clear Alert Number: None.
Related Alert Number: None.
LRA Number: 2081
1204
2079 Virtual disk
initialization
failed
Critical /
Failure /
Error
Cause: A physical disk included in
the virtual disk has failed or a user has
cancelled the initialization.
Action: If a physical disk has failed,
then replace the physical disk.
Clear Alert Number: None.
Related Alert Number: None.
LRA Number: 2081
1204
2080 Physical disk
initialize failed
Critical /
Failure /
Error
Cause: The physical disk has failed or
is corrupt.
Action: Replace the failed or corrupt
disk. You can identify a disk that has
failed by locating the disk that has a
red “X” for its status. Restart the
initialization.
Clear Alert Number: None.
Related Alert Number: None.
LRA Number: 2071
904
Table 4-4. Storage Management Messages (continued)