Messages Reference Guide

72 Storage Management Message Reference
2081 Virtual disk
reconfiguratio
n failed
Critical /
Failure /
Error
Cause: A physical disk included in
the virtual disk has failed or is
corrupt. A user may also have
cancelled the reconfiguration.
Action: Replace the failed or corrupt
disk. You can identify a disk that has
failed by locating the disk that has a
red “X” for its status.
If the physical disk is part of a
redundant array, then rebuild the
physical disk. When finished, restart
the reconfiguration.
Clear Alert Number: None.
Related Alert Number: None.
LRA Number: 2081
1204
2082 Virtual disk
rebuild failed
Critical /
Failure /
Error
Cause: A physical disk included in
the virtual disk has failed or is
corrupt. A user may also have
cancelled the rebuild.
Action: Replace the failed or corrupt
disk. You can identify a disk that has
failed by locating the disk that has a
red “X” for its status. Restart the
virtual disk rebuild.
Clear Alert Number: None.
Related Alert Number: 2048
LRA Number: 2081
1204
2083 Physical disk
rebuild failed
Critical /
Failure /
Error
Cause: A physical disk included in
the virtual disk has failed or is
corrupt. A user may also have
cancelled the rebuild.
Action: Replace the failed or corrupt
disk. You can identify a disk that has
failed by locating the disk that has a
red “X” for its status. Rebuild the
virtual disk rebuild.
Clear Alert Number: None.
Related Alert Number: None.
LRA Number: 2071
904
2085 Virtual disk
check
consistency
completed
Ok / Normal Cause: This alert is for informational
purposes.
Action: None
Clear Alert Status: Alert 2085 is
a clear alert for alert 2058.
Related Alert Number: None.
LRA Number: None.
1201
Table 4-4. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action Related Alert Information SNMP
Trap