Messages Reference Guide

Storage Management Message Reference 77
2106 Smart FPT
exceeded
Warning /
Non-critical
Cause: A disk on the specified
controller has received a SMART
alert (predictive failure) indicating
that the disk is likely to fail in the
near future.
Action: Replace the disk that has
received the SMART alert. If the
physical disk is a member of a non-
redundant virtual disk, then back up
the data before replacing the disk.
NOTICE: Removing a physical
disk that is included in a non-
redundant virtual disk will cause
the virtual disk to fail and may
cause data loss.
Clear Alert Number: None.
Related Alert Number: None.
LRA Number: 2070
903
2107 Smart
configuration
change
Critical /
Failure /
Error
Cause: A disk has received a SMART
alert (predictive failure) after a
configuration change. The disk is
likely to fail in the near future.
Action: Replace the disk that has
received the SMART alert. If the
physical disk is a member of a non-
redundant virtual disk, then back up
the data before replacing the disk.
NOTICE: Removing a physical
disk that is included in a non-
redundant virtual disk will cause
the virtual disk to fail and may
cause data loss.
Clear Alert Number: None.
Related Alert Number: None.
LRA Number: 2071
904
Table 4-4. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action Related Alert Information SNMP
Trap
Numbers