Messages Reference Guide

98 Storage Management Message Reference
2180 The controller
battery Learn
cycle will start
in %1 days.
Ok / Normal Cause: This alert is for informational
purposes. The %1 indicates a
substitution variable. The text for
this substitution variable is displayed
with the alert in the Alert Log and
can vary depending on the situation.
Action: None
Clear Alert Number: None.
Related Alert Number: None.
LRA Number: None.
1151
2181 The controller
battery Learn
cycle will start
in %1 hours.
Ok / Normal Cause: This alert is for informational
purposes. The %1 indicates a
substitution variable. The text for
this substitution variable is displayed
with the alert in the Alert Log and
can vary depending on the situation.
Action: None
Clear Alert Number: None.
Related Alert Number: None.
LRA Number: None.
1151
2182 An invalid SAS
configuration
has been
detected.
Critical /
Failure /
Error
Cause: The controller and attached
enclosures are not cabled correctly.
Action: See the hardware
documentation for information on
correct cabling configurations.
Clear Alert Number: None.
Related Alert Number: None.
LRA Number: 2061
754
2186 The controller
cache has been
discarded.
Warni ng /
Non-critical
Cause: The controller has flushed the
cache and any data in the cache has
been lost. This may happen if the
system has memory or battery
problems that cause the controller to
distrust the cache. Although user data
may have been lost, this alert does not
always indicate that relevant or user
data has been lost.
Action: Verify that the battery and
memory are functioning properly.
Clear Alert Number: None.
Related Alert Number: None.
LRA Number: 2060
753
2187 Single-bit
ECC error
limit exceeded.
Warni ng /
Non-critical
Cause: The system memory is
malfunctioning.
Action: Replace the battery pack.
Clear Alert Number: None.
Related Alert Number: None.
LRA Number: 2060
753
Table 4-4. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action Related Alert Information SNMP
Trap
Numbers