User's Manual

omconfig: Managing Components Using the Instrumentation Service 109
Index
Index refers to the number of an event for a particular component. Index is an
optional parameter. When you omit the index parameter, events are configured
for all components of the specified type, such as all fans. For example, when a
system contains more than one fan, you can enable or disable event notification
for a particular fan. An example command is as follows:
omconfig system events type=fan index=0 severity=
critical
or
omconfig servermodule events type=fan index=0
severity=critical
As a result of the example command, Server Administrator sends an SNMP
trap only when the first fan in the system chassis (index 0) has reached critical
fan RPMs.
omconfig system webserver/omconfig servermodule webserver
Use the omconfig system webserver or omconfig servermodule webserver
command to start or stop the Web server. Table 4-27 shows the valid
parameters for the command.
omconfig system events type=
<component name> severity=critical
or
omconfig servermodule events type=
<component name> severity=critical
Enables notification
for critical events only.
Restrictive form of event
notification.
omconfig system events type=
<component name> severity=none
or
omconfig servermodule events type=
<component name> severity=none
Disables event
notification.
No event notification.
Table 4-27. Web Server Configuration Parameters
name=value pair Description
action=start Starts the Web server.
action=stop Stops the Web server.
action=restart Restarts the Web server.
Table 4-26. System Event Severity Parameters (continued)
Command Result Description