User's Manual

Using the Storage Management Service 185
omconfig Battery Commands
The following sections provide the omconfig command syntax required to
execute battery tasks.
omconfig Recondition Battery
Use the following omconfig command to recondition a controller battery. See
Dell OpenManage Online Help for more information on batteries and the
recondition process.
Complete Syntax
omconfig storage battery action=recondition
controller=id battery=id
where id is the controller ID and battery ID as reported by the omreport
command. To obtain this value, enter omreport storage controller to display
the controller IDs and then enter omreport storage battery controller=ID to
display the ID for the controller battery.
Example Syntax
To recondition the battery on controller 1, enter:
omconfig storage battery action=recondition
controller=1 battery=0
omconfig Start Battery Learn Cycle
Use the following omconfig command to start the battery learn cycle.
Complete Syntax
omconfig storage battery action=startlearn
controller=id battery=id
Table 6-24. omconfig Battery Commands
Required Command Levels (1, 2, 3) Optional name=value pairs
omconfig storage battery
action=recondition controller=id battery=id
action=startlearn controller=id battery=id
action=delaylearn controller=id battery=id
days=d hours=h