User's Manual

186 Using the Storage Management Service
where id is the controller ID and battery ID as reported by the omreport
command. To obtain this value, enter omreport storage controller to display
the controller IDs and then enter omreport storage battery controller=ID to
display the ID for the controller battery.
Example Syntax
To start the learn cycle on controller 1, enter:
omconfig storage battery action=startlearn
controller=1 battery=0
omconfig Delay Battery Learn Cycle
Use the following omconfig command to delay the battery learn cycle for a
specified period of time. The battery learn cycle can be delayed for a
maximum of seven days or 168 hours.
Complete Syntax
omconfig storage battery action=delaylearn
controller=id battery=id
days=d hours=h
where id is the controller ID and battery ID as reported by the omreport
command. To obtain this value, enter omreport storage controller to display
the controller IDs and then enter omreport storage battery controller=ID to
display the ID for the controller battery.
Example Syntax
To delay the learn cycle for three days and 12 hours on controller 1, enter:
omconfig storage battery action=delaylearn
controller=1 battery=0
days=3 hours=12