User's Manual

omconfig: Managing Components Using the Instrumentation Service 85
enablenic=true | false true: Enables DRAC NIC.
false: Disables DRAC NIC
NOTE: The enablenic option is supported on
PowerEdge x9xx systems that have DRAC 5
installed.
IP address=IP ip: Sets the IP address if you have selected
static as the IP address source for the BMC
LAN interface.
config=nic
(continued)
ipsource=static | dhcp |
systemsoftware
static: Static if the IP address of the BMC
LAN interface is a fixed, assigned IP address.
dhcp: DHCP if the source of the IP address
of the BMC LAN interface is the dynamic
host configuration protocol.
systemsoftware: System software if the source
of the IP address of the BMC LAN interface
is from the system software.
NOTE: Not all commands may be supported
on your system.
nicselection=nic1 |
teamednic1nic2 | dracnic
nic1: Enables NIC 1.
teamednic1nic2: Enables NIC teaming
functionality.
dracnic: Enables DRAC NIC if DRAC 5 is
installed.
NOTE: The nicselection option is supported
only on PowerEdge x9xx systems.
privilegelevel=administrator
| operator | user
administrator: Sets the maximum privilege
level that can be accepted on a LAN channel
to Administrator.
operator: Sets the maximum privilege level
that can be accepted on a LAN channel
to Operator.
user: Sets the maximum privilege level that
can be accepted on a LAN channel to User.
subnet=Subnet subnet: Sets a subnet mask if you have
selected static as the IP address source for the
BMC LAN interface.
Table 4-11. omconfig chassis remoteaccess/omconfig mainsystem
remoteaccess (continued)
name=value pair 1
config=
name=value pair 2 Description