Users Guide

114 Remote Access Controller
Configuring the SNMP Alert Properties
NOTE: You must have Administrator privileges in Server Administrator to use the
Remote Access Controller.
To configure the Remote Access Controller alert properties, perform the
following steps:
1
Click
Modular Enclosure
System/Server Module
Main System
Chassis/Main System
Remote Access
and then click the
Configuration
tab.
2
Click
SNMP
.
3
Click
Add
or click the
Destination IP Address
to edit existing SNMP alert
properties.
4
Select the check box next to
Enable SNMP Trap
, if it is not already
selected.
5
Enter the SNMP community name to which the destination management
station belongs in the
Community
field.
6
Enter a destination IP address of the management station to which you
want the DRAC to send SNMP traps when an event occurs in the
IP Address
field.
7
Use the check boxes under
Severity Configuration
to specify the events
and the severity level that those events must have to trigger an alert action
from the DRAC.
The first (left-most) column of check boxes corresponds to the severity
level
Informational
, the second column corresponds to the severity level
Warning
, and the third column corresponds to the severity level
Critical
.
The last seven events can only report the severity level
Informational
.
8
Click
Apply Changes
and then click
OK
to save your changes.