Messages Reference Guide

Storage Management Message Reference 103
2094 Predictive
Failure
reported.
Warning /
Non-
critical
Cause: The physical disk is
predicted to fail. Many
physical disks contain Self
Monitoring Analysis and
Reporting Technology
(SMART). When enabled,
SMART monitors the
health of the disk based on
indications such as the
number of write operations
that have been performed
on the disk.
Action: Replace the
physical disk. Even though
the disk may not have
failed yet, it is strongly
recommended that you
replace the disk.
If this disk is part of a
redundant virtual disk,
perform the Offline task
on the disk; replace the
disk; and then assign a hot
spare and the rebuild will
start automatically.
Clear Alert
Number:
None.
Related Alert
Number:
None.
LRA Number:
2070
903
Table 4-4. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action Related Alert
Information
SNMP
Trap