Messages Reference Guide

Storage Management Message Reference 105
2099 Global hot
spare
unassigned
OK /
Normal
Cause: A user has
unassigned a physical disk
as a global hot spare. This
alert is for informational
purposes.
Action: None
Clear Alert
Number:
None.
Related Alert
Number:
None.
LRA Number:
None.
901
2100 Temperature
exceeded
the
maximum
warning
threshold
Warning /
Non-
critical
Cause: The physical disk
enclosure is too hot.
A variety of factors can
cause the excessive
temperature. For example,
a fan may have failed, the
thermostat may be set too
high, or the room
temperature may be too
hot.
Action: Check for factors
that may cause
overheating. For example,
verify that the enclosure
fan is working. You should
also check the thermostat
settings and examine
whether the enclosure is
located near a heat source.
Make sure the enclosure
has enough ventilation and
that the room temperature
is not too hot. See the
physical disk enclosure
documentation for more
diagnostic information.
Clear Alert
Number: 2353.
Related Alert
Number: 2112
LRA Number:
2090
1053
Table 4-4. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action Related Alert
Information
SNMP
Trap
Numbers