Messages Reference Guide

106 Storage Management Message Reference
2101 Temperature
dropped
below the
minimum
warning
threshold
Warning /
Non-
critical
Cause: The physical disk
enclosure is too cool.
Action: Check if the
thermostat setting is too
low and if the room
temperature is too cool.
Clear Alert
Number: 2353.
Related Alert
Number:
None.
LRA Number:
2090
1053
2102 Temperature
exceeded
the
maximum
failure
threshold
Critical /
Failure /
Error
Cause: The physical disk
enclosure is too hot. A
variety of factors can cause
the excessive temperature.
For example, a fan may
have failed, the thermostat
may be set too high, or the
room temperature may be
too hot.
Action: Check for factors
that may cause
overheating. For example,
verify that the enclosure
fan is working. You should
also check the thermostat
settings and examine
whether the enclosure is
located near a heat source.
Make sure the enclosure
has enough ventilation and
that the room temperature
is not too hot. See the
physical disk enclosure
documentation for more
diagnostic information.
Clear Alert
Number:
None.
Related Alert
Number:
None.
LRA Number:
2091
1054
Table 4-4. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action Related Alert
Information
SNMP
Trap
Numbers