Messages Reference Guide

Storage Management Message Reference 111
2109 SMART
warning
temperature
Warning /
Non-
critical
Cause: A disk has reached
an unacceptable
temperature and received a
SMART alert (predictive
failure). The disk is likely to
fail in the near future.
Action 1: Determine why
the physical disk has
reached an unacceptable
temperature. A variety of
factors can cause the
excessive temperature. For
example, a fan may have
failed, the thermostat may
be set too high, or the room
temperature may be too
hot or cold. Verify that the
fans in the server or
enclosure are working. If
the physical disk is in an
enclosure, you should check
the thermostat settings and
examine whether the
enclosure is located near a
heat source.
Clear Alert
Number:
None.
Related Alert
Number:
None.
LRA Number:
2070
903
Table 4-4. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action Related Alert
Information
SNMP
Trap
Numbers