Messages Reference Guide

Storage Management Message Reference 119
2123 Redundancy
lost
Warning /
Non-
critical
Cause: A virtual disk or an
enclosure has lost data
redundancy. In the case of a
virtual disk, one or more
physical disks included in
the virtual disk have failed.
Due to the failed physical
disk or disks, the virtual
disk is no longer
maintaining redundant
(mirrored or parity) data.
The failure of an additional
physical disk will result in
lost data. In the case of an
enclosure, more than one
enclosure component has
failed. For example, the
enclosure may have
suffered the loss of all fans
or all power supplies.
Action: Identify and
replace the failed
components. To identify the
failed component, select
the Storage object and click
the Health subtab.
Clear Alert
Number: 2124.
Related Alert
Number: 2048,
2049, 2057
LRA Number:
2080, 2090
1306
Table 4-4. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action Related Alert
Information
SNMP
Trap
Numbers