Messages Reference Guide

138 Storage Management Message Reference
2171 The
controller
battery
temperature
is above
normal.
Warning /
Non-
critical
Cause: The battery may be
recharging, the room
temperature may be too
hot, or the fan in the
system may be degraded or
failed.
Action: If this alert was
generated due to a battery
recharge, the situation will
correct when the recharge
is complete. You should
also check if the room
temperature is normal and
that the system
components are
functioning properly.
Clear Alert
Number: 2172.
Related Alert
Number:
None.
LRA Number:
2100
1153
2172 The
controller
battery
temperature
is normal.
OK /
Normal
Cause: This alert is for
informational purposes.
Action: None
Clear Alert
Status: Alert
2172 is a clear
alert for alert
2171.
Related Alert
Number:
None.
LRA Number:
None.
1151
Table 4-4. Storage Management Messages (continued)