Messages Reference Guide

142 Storage Management Message Reference
2178 The
controller
battery
Learn cycle
has
timed out.
Warning /
Non-
critical
Cause: The controller
battery must be fully
charged before the Learn
cycle can begin. The
battery may be unable to
maintain a full charge
causing the Learn cycle to
timeout. Additionally, the
battery must be able to
maintain cached data for a
specified period of time in
the event of a power loss.
For example, some batteries
maintain cached data for
24 hours. If the battery is
unable to maintain cached
data for the required period
of time, then the Learn
cycle will timeout.
Action: Replace the battery
pack as the battery is
unable to maintain a full
charge.
Clear Alert
Number:
None.
Related Alert
Number:
None.
LRA Number:
2100
1153
2179 The
controller
battery
Learn cycle
has been
postponed.
OK /
Normal
Cause: This alert is for
informational purposes.
Action: None
Clear Alert
Number:
None.
Related Alert
Number:
None.
LRA Number:
None.
1151
Table 4-4. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action Related Alert
Information
SNMP
Trap
Numbers