Messages Reference Guide

152 Storage Management Message Reference
2203 A dedicated
hot spare
failed.
Warning /
Non-
critical
Cause: The controller is
unable to communicate
with a disk that is assigned
as a dedicated hot spare.
The disk may have failed or
been removed. There may
also be a bad or loose cable.
Action: Check if the disk is
healthy and that it has not
been removed. Check the
cables. If necessary, replace
the disk and reassign the
hot spare.
Clear Alert
Number:
None.
Related Alert
Number: 2048
LRA Number:
2070
903
2204 A dedicated
hot spare has
been
removed.
OK /
Normal
Cause: The controller is
unable to communicate with
a disk that is assigned as a
dedicated hot spare. The
disk may have been
removed. There may also
be a bad or loose cable.
Action: Check if the disk is
healthy and that it has not
been removed. Check the
cables. If necessary, replace
the disk and reassign the
hot spare.
Clear Alert
Number:
None.
Related Alert
Number:
None.
LRA Number:
None.
901
2205 A dedicated
hot spare has
been
automaticall
y
unassigned.
OK /
Normal
Cause: The hot spare is no
longer required because the
virtual disk it was assigned
to has been deleted.
Action: None.
Clear Alert
Number:
None.
Related Alert
Number: 2098,
2161, 2196
LRA Number:
None.
901
Table 4-4. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action Related Alert
Information
SNMP
Trap
Numbers