Messages Reference Guide

168 Storage Management Message Reference
2255 The physical
disk has
been started.
OK /
Normal
Cause: This alert is for
informational purposes.
Action: None
Clear Alert
Number:
None.
Related Alert
Number: 2048,
2050, 2065,
2099, 2121,
2196, 2201,
2203
LRA Number:
None.
901
2257 Controller
preserved
cache is
discarded
Warning Cause: The controller
cache is discarded by the
user.
Action: None
Clear Alert
Number:
None.
Related Alert
Number:
None.
LRA Number:
None.
753
2258 Controller
has
preserved
cache
Warning Cause: IO interrupted for a
virtual disk which is
connected to the controller.
Action: Check for foreign
configuration and import if
any. Check for cable fault.
Recover any virtual disk
lost by the controller.
Clear Alert
Number:
None.
Related Alert
Number:
None.
LRA Number:
None.
753
Table 4-4. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action Related Alert
Information