Messages Reference Guide

178 Storage Management Message Reference
2282 Hot spare
SMART
polling
failed.
Critical /
Failure /
Error
Cause: The controller
firmware attempted a
SMART polling on the hot
spare but was unable to
complete it. The controller
has lost communication
with the hot spare.
Action: Check the health
of the disk assigned as a hot
spare. You may need to
replace the disk and
reassign the hot spare.
Make sure the cables are
attached securely. See the
Cables Attached Correctly
section in the
Dell OpenManage Server
Administrator Storage
Management User’s Guide
for more information on
checking the cables.
Clear Alert
Number:
None.
Related Alert
Number:
None.
LRA Number:
2071
904
2283 A redundant
path is
broken.
Warning /
Non-
critical
Cause: The controller has
two connectors that are
connected to the same
enclosure. The
communication path on
one connector has lost
connection with the
enclosure. The
communication path on
the other connector is
reporting this loss.
Action: Make sure the
cables are attached
securely. Make sure both
EMMs are healthy.
Clear Alert
Number: 2284.
Related Alert
Number:
None.
LRA Number:
2070
903
Table 4-4. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action Related Alert
Information
SNMP
Trap
Numbers