Messages Reference Guide

18 Event Message Reference
1004 Thermal shutdown
protection has been
initiated
Error This message is generated
when a system is configured
for thermal shutdown due
to an error event. If a
temperature sensor reading
exceeds the error threshold
for which the system is
configured, the operating
system shuts down and
the system powers off.
This event may also be
initiated on certain systems
when a fan enclosure is
removed from the system for
an extended period of time.
1005 SMBIOS data is absent Warning The system does not contain
the required systems
management BIOS version
2.2 or higher, or the BIOS is
corrupted.
1006 Automatic System
Recovery (ASR) action
was performed
Action performed was:
<Action>
Date and time of
action:
<Date and time>
Error This message is generated
when an automatic system
recovery action is performed
due to a hung operating
system. The action
performed and the time of
action are provided.
1007 User initiated host
system control action
Action requested was:
<Action>
Information User requested a host system
control action to reboot,
power off, or power cycle the
system. Alternatively the
user had indicated protective
measures to be initiated in
the event of a thermal
shutdown.
Table 2-1. Miscellaneous Messages (continued)
Event
ID
Description Severity Cause