Messages Reference Guide

190 Storage Management Message Reference
2311 The
firmware on
the EMMs is
not the same
version.
EMM0 %1
EMM1 %2
Warning /
Non-
critical
Cause: The firmware on
the EMM modules is not
the same version. It is
required that both modules
have the same version of
the firmware. This alert
may be caused if you
attempt to insert an EMM
module that has a different
firmware version than an
existing module. The %1
and %2 indicate a
substitution variable. The
text for these substitution
variables is displayed with
the alert in the Alert Log
and can vary depending on
the situation.
Action: Upgrade to the
same version of the
firmware on both EMM
modules.
Clear Alert
Number:
None.
Related Alert
Number:
None.
LRA Number:
2090
853
2312 A power
supply in the
enclosure
has an
AC failure.
Warning /
Non-
critical
Cause: The power supply
has an AC failure.
Action: Replace the power
supply.
Clear Alert
Number: 2325.
Related Alert
Number: 2122,
2324.
LRA Number:
2090
1003
Table 4-4. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action Related Alert
Information
SNMP