Messages Reference Guide

Storage Management Message Reference 195
2323 The power
supply is
switched on.
OK /
Normal
Cause: This alert is for
informational purposes.
Action: None
Clear Alert
Status: Alert
2323 is a clear
alert for alerts
2313 and 2322.
Related Alert
Number:
None.
LRA Number:
None.
1001
2324 The AC
power
supply cable
has been
removed.
Critical /
Failure /
Error
Cause: The power cable
may be pulled out
or removed. The power
cable may also have
overheated and become
warped and nonfunctional.
Action: Replace the power
cable.
Clear Alert
Number: 2325.
Related Alert
Number:
None.
LRA Number:
2091
1004
2325 The power
supply cable
has been
inserted.
Ok /
Normal
Cause: This alert is for
informational purposes.
Action: None
Clear Alert
Status: Alert
2325 is a clear
alert for alerts
2324 and 2312.
Related Alert
Number:
None.
LRA Number:
None.
1001
Table 4-4. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action Related Alert
Information
SNMP
Trap
Numbers