Messages Reference Guide

196 Storage Management Message Reference
2326 A foreign
configuratio
n has been
detected.
OK /
Normal
Cause: This alert is for
informational purposes.
The controller has physical
disks that were moved from
another controller. These
physical disks contain
virtual disks that were
created on the other
controller. See the Import
Foreign Configuration and
Clear Foreign
Configuration section in the
Dell OpenManage Server
Administrator Storage
Management User’s Guide
for more information.
Action: None
Clear Alert
Number:
None.
Related Alert
Number:
None.
LRA Number:
None.
751
2327 The
NVRAM has
corrupted
data. The
controller is
reinitializing
the
NVRAM.
Warning /
Non-
critical
Cause: The NVRAM has
corrupted data. This may
occur after a power surge, a
battery failure, or for other
reasons. The controller is
reinitializing the NVRAM.
Action: None. The
controller is taking the
required corrective action.
If this alert is generated
often (such as during each
reboot), replace the
controller.
Clear Alert
Number:
None.
Related Alert
Number: 2266
LRA Number:
2060
753
Table 4-4. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action Related Alert
Information
SNMP
Trap