Messages Reference Guide

198 Storage Management Message Reference
2330 SAS port
report: %1
OK /
Normal
Cause: This alert is for
informational purposes.
The %1 indicates a
substitution variable. The
text for this substitution
variable is generated by the
controller and is displayed
with the alert in the Alert
Log. This text can vary
depending on the
situation.
Action: None
Clear Alert
Number:
None.
Related Alert
Number:
None.
LRA Number:
None.
751
2331 A bad disk
block has
been
reassigned.
OK /
Normal
Cause: The disk has a bad
block. Data has been
readdressed to another disk
block and no data loss has
occurred.
Action: Monitor the disk
for other alerts or
indications of poor health.
For example, you may
receive alert 2306. Replace
the disk if you suspect
there is a problem.
Clear Alert
Number:
None.
Related Alert
Number:
None.
LRA Number:
None.
901
2332 A controller
hot plug has
been
detected.
OK /
Normal
Cause: This alert is for
informational purposes.
Action: None
Clear Alert
Number:
None.
Related Alert
Number:
None.
LRA Number:
None.
751
Table 4-4. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action Related Alert
Information
SNMP
Trap
Numbers