Messages Reference Guide

Storage Management Message Reference 201
2336 Controller
event
log: %1
Critical /
Failure /
Error
Cause: The %1 indicates a
substitution variable. The
text for this substitution
variable is generated by the
controller and is displayed
with the alert in the Alert
Log. This text is from
events in the controller
event log that were
generated while Storage
Management was not
running. This text can vary
depending on the
situation.
Action: See the hardware
documentation for more
information.
Clear Alert
Number:
None.
Related Alert
Number:
None.
LRA Number:
2061
754
2337 The
controller is
unable to
recover
cached data
from the
battery
backup unit
(BBU).
Critical /
Failure /
Error
Cause: The controller was
unable to recover data from
the cache.
Action: Check if the
battery is charged and in
good health. When the
battery charge is
unacceptably low, it cannot
maintain cached data.
Check if the battery has
reached its recharge limit.
The battery may need to be
recharged or replaced.
Clear Alert
Number:
None.
Related Alert
Number:
None.
LRA Number:
2101
1154
Table 4-4. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action Related Alert
Information
SNMP