Messages Reference Guide

Storage Management Message Reference 205
2346 Error
occurred: %1
Warning /
Non-
critical
Cause: A physical device
may have an error. The %1
indicates a substitution
variable. The text for this
substitution variable is
generated by the firmware
and is displayed with the
alert in the Alert Log. This
text can vary depending on
the situation.
Action: Verify the health of
attached devices. Review
the Alert Log for
significant events. Run the
PHY integrity diagnostic
tests. You may need to
replace faulty hardware.
Make sure the cables are
attached securely. See the
hardware documentation
for more information.
Clear Alert
Number:
None.
Related Alert
Number: 2048,
2050, 2056,
2057, 2076,
2079, 2081,
2083, 2095,
2129, 2201,
2203, 2270,
2282, 2369
LRA Number:
2070
903
2347 The rebuild
failed due to
errors on the
source
physical
disk.
Critical /
Failure /
Error
Cause: You are attempting
to rebuild data that resides
on a defective disk.
Action: Replace the source
disk and restore from
backup.
Clear Alert
Number:
None.
Related Alert
Number: 2195,
2346
LRA Number:
2071
904
Table 4-4. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action Related Alert
Information
SNMP
Trap
Numbers