Messages Reference Guide

206 Storage Management Message Reference
2348 The rebuild
failed due to
errors on the
target
physical
disk.
Critical /
Failure /
Error
Cause: You are attempting
to rebuild data on a disk
that is defective.
Action: Replace the target
disk. If a rebuild does not
automatically start after
replacing the disk, initiate
the Rebuild task. You may
need to assign the new disk
as a hot spare to initiate the
rebuild.
Clear Alert
Number:
None.
Related Alert
Number: 2195,
2346
LRA Number:
2071
904
2349 A bad disk
block could
not be
reassigned
during a
write
operation.
Critical /
Failure /
Error
Cause: A write operation
could not complete
because the disk contains
bad disk blocks that could
not be reassigned. Data loss
may have occurred and
data redundancy may also
be lost.
Action: Replace the disk.
Clear Alert
Number:
None.
Related Alert
Number: 2346
LRA Number:
2071
904
2350 There was
an
unrecoverabl
e disk media
error during
the rebuild.
Critical /
Failure /
Error
Cause: The rebuild
encountered an
unrecoverable disk media
error.
Action: Replace the disk.
Clear Alert
Number:
None.
Related Alert
Number: 2095,
2273
LRA Number:
2071
904
Table 4-4. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action Related Alert
Information
SNMP
Trap
Numbers