Messages Reference Guide

Event Message Reference 21
1052 Temperature sensor returned
to a normal value
Sensor location:
<Location
in chassis>
Chassis location:
<Name of
chassis>
Previous state was:
<State>
If sensor type is not
discrete:
Temperature sensor value (in
degrees Celsius):
<Reading>
If sensor type is discrete:
Discrete temperature state:
<State>
Information A temperature sensor
on the backplane
board, system board,
or drive carrier in the
specified system
returned to a valid
range after crossing
a failure threshold.
The sensor location,
chassis location,
previous state, and
temperature sensor
value are provided.
1053 Temperature sensor detected
a warning value
Sensor location:
<Location
in chassis>
Chassis location:
<Name of
chassis>
Previous state was:
<State>
If sensor type is not
discrete:
Temperature sensor value (in
degrees Celsius):
<Reading>
If sensor type is discrete:
Discrete temperature state:
<State>
Warning A temperature sensor
on the backplane
board, system board,
CPU, or drive carrier
in the specified
system exceeded its
warning threshold.
The sensor location,
chassis location,
previous state, and
temperature sensor
value are provided.
Table 2-2. Temperature Sensor Messages (continued)
Event
ID
Description Severity Cause