Messages Reference Guide

212 Storage Management Message Reference
2367 Rebuild not
possible as
SAS/SATA is
not
supported in
the same
virtual disk.
Warning /
Non-
critical
Cause: The physical disk is
using an incompatible
technology.
Action: All physical disks in
the virtual disk must use
the same technology. You
cannot use both SAS and
SATA physical disks in the
same virtual disk. Remove
the physical disk and insert
a new physical disk that
uses the correct technology.
If the rebuild does not start
automatically after you
have inserted a suitable
physical disk, then run the
Rebuild task.
Clear Alert
Number:
None.
Related Alert
Number: 2326
LRA Number:
2070
903
2368 The SCSI
Enclosure
Processor
(SEP) has
been
rebooted as
part of the
firmware
download
operation
and will be
unavailable
until the
operation
completes.
OK /
Normal
Cause: This alert is for
informational purposes.
Action: None.
Clear Alert
Number:
None.
Related Alert
Number: 2049,
2052, 2162,
2292
LRA Number:
None.
851