Messages Reference Guide

Storage Management Message Reference 79
Table 4-2. Message Format with Variables for Each Storage Object
Storage Object Message Variables
A, B, C and X, Y, Z in the following examples are variables
representing the storage object name or number.
Controller Message Format: Controller A (Name)
Message Format: Controller A
Example: 2326 A foreign configuration has been detected.:
Controller 1 (PERC 5/E Adapter)
NOTE: The controller name is not always displayed.
Battery Message Format: Battery X Controller A
Example: 2174 The controller battery has been removed: Battery 0
Controller 1
SCSI Physical
Disk
Message Format: Physical Disk X:Y Controller A, Connector B
Example: 2049 Physical disk removed: Physical Disk 0:14 Controller
1, Connector 0
SAS Physical
Disk
Message Format: Physical Disk X:Y:Z Controller A, Connector B
Example: 2049 Physical disk removed: Physical Disk 0:0:14
Controller 1, Connector 0
Virtual Disk Message Format: Virtual Disk X (Name) Controller A (Name)
Message Format: Virtual Disk X Controller A
Example: 2057 Virtual disk degraded: Virtual Disk 11 (Virtual Disk
11) Controller 1 (PERC 5/E Adapter)
NOTE: The virtual disk and controller names are not always
displayed.
Enclosure: Message Format: Enclosure X:Y Controller A, Connector B
Example: 2112 Enclosure shutdown: Enclosure 0:2 Controller 1,
Connector 0