Messages Reference Guide

Storage Management Message Reference 87
Alert Descriptions and Corrective Actions
The following sections describe alerts generated by the RAID or SCSI
controllers supported by Storage Management. The alerts are displayed in the
Server Administrator Alert subtab or through Windows Event Viewer. These
alerts can also be forwarded as SNMP traps to other applications.
SNMP traps are generated for the alerts listed in the following sections.
These traps are included in the Dell OpenManage Server Administrator
Storage Management management information base (MIB). The SNMP
traps for these alerts use all of the SNMP trap variables. For more information
on SNMP support and the MIB, see the SNMP Reference Guide.
To locate an alert, scroll through the following table to find the alert number
displayed on the Server Administrator Alert tab or search this file for the alert
message text or number. See "Understanding Event Messages" for more
information on severity levels.
For more information regarding alert descriptions and the appropriate
corrective actions, see the online help.
Table 4-4. Storage Management Messages
Event
ID
Description Severity Cause and Action Related Alert
Information
SNMP
Trap
Numbers
2048 Device
failed
Critical /
Failure /
Error
Cause: A storage
component such as
a physical disk or an
enclosure has failed.
The failed component may
have been identified by the
controller while performing
a task such as a rescan or
a check consistency.
Action: Replace the failed
component. You can
identify which disk has
failed by locating the disk
that has a red “X” for its
status. Perform a rescan
after replacing the disk.
Clear Alert
Number: 2121.
Related Alert
Number: 2095,
2201, 2203
LRA Number:
2051, 2061,
2071, 2081,
2091, 2101
754
804
854
904
954
1004
1054
1104
1154
1204