Messages Reference Guide

Storage Management Message Reference 89
2050 Physical disk
offline
Warning /
Non-
critical
Cause: A physical disk in
the disk group is offline.
A user may have manually
put the physical disk
offline.
Action: Perform a rescan.
You can also select the
offline disk and perform
a Make Online operation.
Clear Alert
Number: 2158.
Related Alert
Number: 2099,
2196
LRA Number:
2070
903
2051 Physical disk
degraded
Warning /
Non-
critical
Cause: A physical disk has
reported an error condition
and may be degraded.
The physical disk may
have reported the error
condition in response to
a consistency check or
other operation.
Action: Replace the
degraded physical disk.
You can identify which disk
is degraded by locating the
disk that has a red "X" for
its status. Perform a rescan
after replacing the disk.
Clear Alert
Number:
None.
Related Alert
Number: 2070
LRA Number:
None.
903
2052 Physical disk
inserted
OK /
Normal
Cause: This alert is for
informational purposes.
Action: None
Clear Alert
Number:
None.
Related Alert
Number: 2065,
2305, 2367
LRA Number:
None.
901
Table 4-4. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action Related Alert
Information
SNMP
Trap