Messages Reference Guide

Storage Management Message Reference 91
2056 Virtual disk
failed
Critical /
Failure /
Error
Cause: One or more
physical disks included in
the virtual disk have failed.
If the virtual disk is
non-redundant (does not
use mirrored or parity data),
then the failure of a single
physical disk can cause the
virtual disk to fail. If the
virtual disk is redundant,
then more physical disks
have failed than can be
rebuilt using mirrored or
parity information.
Action:
Create a new virtual
disk and restore from a
backup.
controller, rebuild the
virtual disk by first
configuring a hot spare for
the disk, and then
initiating a write operation
to the disk. The write
operation will initiate a
rebuild of the disk.
Clear Alert
Number:
None.
Related Alert
Number: 2048,
2049, 2050,
2076, 2079,
2081, 2129,
2346
LRA Number:
2081
1204
Table 4-4. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action Related Alert
Information
SNMP
Trap
Numbers